The brief says "no Wi-Fi." The memo's fourth belief — "We don't have control over the propagation of our words once recorded" — means every path off the device is a path the room loses control over. Bluetooth would bring back silent sync to a phone and, with it, most of the distrust Goldfish exists to remove.
| Option | For | Against |
|---|---|---|
| No radio at all | Simplest trust story ("it can't send anything"); certification as an unintentional radiator only (FCC Part 15 Subpart B / CE EMC) | Preferences and export need a wired or contact path |
| NFC only | Touch-range, natural "in the room" gesture for tokens and phones | Intentional radiator — adds certification; still a radio in the story |
| BLE | Phone app, easy UX | Contradicts the brief in spirit |
No radio of any kind in v1, including NFC.
# ADR-0001: No wireless radio in v1
- **Status:** accepted, amended by ADR-0007 (a passive NFC tag, RF disabled except while the read button is held)
- **Date:** 2026-10-12
- **Requirements touched:** P-09, S-01, S-07
## Context
The brief says "no Wi-Fi." The memo's fourth belief — "We don't have control over the propagation of our words once recorded" — means every path off the device is a path the room loses control over. Bluetooth would bring back silent sync to a phone and, with it, most of the distrust Goldfish exists to remove.
## Options
| Option | For | Against |
|---|---|---|
| No radio at all | Simplest trust story ("it can't send anything"); certification as an unintentional radiator only (FCC Part 15 Subpart B / CE EMC) | Preferences and export need a wired or contact path |
| NFC only | Touch-range, natural "in the room" gesture for tokens and phones | Intentional radiator — adds certification; still a radio in the story |
| BLE | Phone app, easy UX | Contradicts the brief in spirit |
## Decision
No radio of any kind in v1, including NFC.
## Consequences
- Preferences come in by voice (ADR-0003); the device answers with light (ADR-0006).
- Memory is read only through a wired, physically-held connection (ADR-0004).
- An RF scan in the EMC pre-scan becomes a marketing artefact: proof of silence.